<LOGO>
FM Transmitter Measurement Report
Created: 2023-08-31 11-27-24
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.20 MHz 5/5, 51 dBuV RTL
Pilot RDS Phase Difference
0.0 kHz 3.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
4 kHz 69 kHz 19090 0,0576
Modulation Power
Limit Measuring Tolerance
8,0 dBr 1,0 dBr
MIN AVE MAX % above 9,0 dBr
4,4 dBr 5,58 dBr 6,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RTL " F211 0 (No PTY) 1 0 1 2 --:--
RT
-
AF EON
95.3, 99.8, 100.4, 101.3, 103.6, 103.9, 104.0, 104.1, 104.2, 104.3, 105.0, 105.1, 106.0 MHz -
FM Scope Station: 104.20 MHz, signal: 5/5 (51 dBuV) Max at: 69 kHz MIN: 4 kHz % above 75 kHz: 0,0576 Acquired: 2023/08/31 11:26:20 Total samples: 19090 Equivalent time: 0:15:54 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 6,4 dBr MIN: 4,4 dBr AVE: 5,58 dBr % above 9,0 dBr: 0,0 Last value: 5,7 dBr (2023/08/31 11:26:18) Station: 104.20 MHz, signal: 5/5 (51 dBuV) 11:12 11:14 11:16 11:18 11:20 11:22 11:24 11:26 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality